Advanced Electronics Labs Inc.,
Phone:305-255-6401
Fax:877-312-7463
7375 SW 114th Street,
Pinecrest, Florida, 33156
USA
High Speed On-Board Recording Systems (HS OBR) for High G environment
Technology
HS-OBR-12-2G, HS-OBR-9-2G, HS-OBR-6-2G, HS-OBR-3-2G
Dimensions 1 5/8 x 1 11/16 in. or 41x44mm (without pins)
Ultra-High Speed Shock Hardened Miniature Recorders capture High-speed data for ballistics and explosives testing. Data recorded during these ultra-fast events at speeds up to 2MHz per data channel, allowing very high precision modeling and analysis of monitored processes. Model HS-OBR-3-2G is a miniaturized, single board, high shock, solid-state recorder designed to acquire transducer data in shock environments of up to 100,000 G's. Single boards could be easily interconnected providing unlimited data channel capability. Boards can be configured for a variety of transducer inputs to accommodate testing in harsh environments such as: oil exploration work, automotive crash testing, blast testing, armaments testing and development. Epoxy-encapsulated option is available as well as single or multi-board configurations. Low power consumption and use of nonvolatile High Capacity Flash Memory allows instrumentation to collect data for long duration processes and to retrieve data any time after test even if the power was lost. Data retrieval is accomplished using a personal computer. Software supplied with the recorder enables storage, display, zooming and printing of the data. Factory Software upgrades are available in option with programming connector.
Made in USA. MIL-PRF-55110G compliant.
Up to 12GB of non-volatile memory with unlimited pre-trigger points will provide sufficient amount of storage space for acquired data.
Channel filtering is adjustable based on sampling frequency is available.
The So What
Our state-of-the-art device will provide unparalleled functionalities, accuracy, and flexibility in data acquisition in harsh environment. Monitoring and recording data from sensors such us accelerometers, strain gauges, pressure transducers will be greatly enhanced and much more reliable.ELECTRICAL SPECIFICATIONS
| Data Input Channels | 12 Analog |
| Analog Amplifier Inputs | Differential, High-impedance |
| Analog Low-Pass Filter | 100 KHz (-3dB), 1-Pole, Low Pass |
| Digitizer Amplitude Resolution | 12 Bits (4096 Digital Steps) |
| Memory Capacity (non-volatile) | Up to 12 GB |
| Pre-Trigger Data Points / Channel | Programmable |
| Fast Speed Sample Rate / Channel | 1 MSPS |
| External Trigger | 3.3 Volt Positive Pulse |
| Internal Trigger (channel level) | Programmable |
| Supply Voltage | 5 to 13 DC Volts |
| Supply Voltage for External Sensor | 3.3 Volts |
| Input Current | Depends on configuration |
| Sleep/Arm Mode Time | Programmable |
PHYSICAL SPECIFICATIONS
Temperature Range: 0° C to 120° CLength: Less than 2.00"
Width: Less than 2.00"
Weight: Model dependent
Maximum Shock Level ±50,000 G's
DATA RETRIEVAL
“Quick Look” application is used to: program the recorder, retrieve, store, display, examine, and print data. The minimum, recommended computer configuration is: Windows XP, a Pentium 5, 1.5 GHz or higher, 1024 x 768 graphics, 80 Gig drive, 1GB RAM, USB port, and printer.Manual
Product Warranty
Download software